At least 52 wrong training labels in MedCalc-Bench Verified that pass a formula re-check

Re-running the formula on 3,794 Verified training rows finds 0 mismatches, against 27 on the same rows of v1.2. Reading the flagged rows against the notes they came from finds at least 52 of 10,538 training labels wrong given their notes: 22 misread from the note, 30 copying a typo the note itself prints. Row 2807's note says pulse 40-50 bpm, and its label scores a heart rate of 4,050. 31 of the 52 sit in calculators the recompute covers, and it passes every one. Only the 194 flagged training rows were read, so 52 is a floor, not an error rate. Separately, a known unit-conversion bug in the HOMA-IR calculator still makes 32 of its 77 training labels 36 times too large.

Row Number 1337, MAP, Verified train. The highlighted words are the note's own text.
Note saysHis blood pressure throughout the episode was 150-160/80-90 mmHg, up from a baseline of 100-130/70-80 mmHg.
Extracted inputsbp = 150160 mm hg
Extracted inputdbp = 8090 mm hg
Stored answer55446.66667as stored in the CSV; rewarded from 52,674 to 58,219
What the note supports80.00 to 113.33 (76.00 to 119.00 with the 5% tolerance)

Red is a stored label. Blue is a value the note supports. Yellow is quoted note text.

MAP is SBP / 3 + 2 × DBP / 3. The stored inputs give 150160 / 3 + 2 × 8090 / 3 = 55,446.67, which is the stored label, so a formula re-check passes it. The note gives two ranges, the one during the seizure and the patient's baseline, and both come before the blood-pressure treatment. Over every pair of their endpoints, MAP runs from 80.00 to 113.33 mmHg, or 76.00 to 119.00 after the dataset's 5% tolerance. A model that reads the note and answers anywhere in that interval gets zero reward, because the label only rewards 52,674 to 58,219. No model has been run on this row yet, so that is arithmetic on the stored limits, not an observed answer.

The Verified pass rewrote some of these labels

The Verified release changed the stored label on 9 of the confirmed rows, with the extracted inputs unchanged. Every new label is still impossible. 8 were re-rounded to more or fewer digits. Row 3211 (MDRD) moved from 12,129.91 to 11,632.93 because of rounding one step earlier: the v1.2 explanation rounded the converted input to 0.012, and Verified kept 0.012443. The note prints creatinine was 1.1 μmol/L, and the old label sits inside the new one's accepted range (11,051 to 12,215). So all 9 are precision changes. None of them touched the impossible input.

Confirmed defects whose stored label differs between v1.2 and Verified, joined on Calculator ID plus Note ID. Labels are as stored in each CSV.
RowCalculatorNote saysv1.2 labelVerified labelChange
267CKD-EPICreatinine was 130 mmol/dl0.000970.00096752label re-rounded
311CKD-EPIcreatinine 120 mmol/L0.016670.016671label re-rounded
409CKD-EPI119 to 270 mmol/L0.00570.0057034label re-rounded
463CKD-EPIaround 200mol/L0.00870.0087006label re-rounded
467CKD-EPIblood creatinine at 127 mmol/L0.011590.011586label re-rounded
3175MDRDcreatinine 877 mol/l4.73784e-074.7378e-07label re-rounded
3211MDRDcreatinine was 1.1 μmol/L12129.906311632.92792intermediate value re-rounded, 0.012 to 0.012443
3337MDRDelevated at 120 mmol/l0.018370.018366label re-rounded
3394MDRDelevated at 254 mmol/L0.009730.0097267label re-rounded

A conversion bug in the HOMA-IR calculator

32 of 77 HOMA-IR training rows give insulin in pmol/L. The explanation converts it to µIU/mL by multiplying by 6, as in row 5880: 756.0 * 6 µIU/mL/pmol/L = 4536.0 µIU/mL. About 6 pmol/L make 1 µIU/mL, so the conversion should divide, and every one of these labels is 36 times too large. They run from 52.85 to 233.81, and 1,089.76 for row 5880, while the HOMA-IR rows in other units top out at 19.9. Row 9797 has insulin 55 pmol/L and a stored label of 76.33; divided instead of multiplied, the same inputs give 2.12.

arXiv 2603.02222 lists this bug, and PR #5 (artuskg) proposed the one-line fix in February 2026. It was closed without merging, so 32 of 77 training labels in v1.0.8 still carry it.

This is a separate count from the 52: 31 of the 32 rows are outside it. The gate does not catch these rows, because the formula is applied consistently to inputs that match the note, and a recompute that runs the same calculator code agrees with the label. The fix belongs in one line of the calculator, not in 32 separate relabels. Every row is listed in results/homa_ir.csv, and results/fix_list.csv marks them "fix the calculator".

Headline numbers

Counts sit next to every share. Intervals are Wilson 95%. Gate precision leaves out rows marked unclear.

Verified train n = 10,538, test n = 1,100. Source: results/results_table.csv.
MeasureSplitCountShare95% CI
Wrong labels given their notes (a floor: only flagged rows were read)train52 of 10,5380.49%
Misread from the notetrain22 of 10,5380.21%
Copying a typo the note itself printstrain30 of 10,5380.28%
Wrong labels given their notes (a floor: only flagged rows were read)test1 of 1,1000.09%
Misread from the notetest0 of 1,1000%
Copying a typo the note itself printstest1 of 1,1000.09%
Formula recompute mismatches, Verified v1.0.8train0 of 3,7940%0% to 0.10%
Formula recompute mismatches, v1.2, same rowstrain27 of 3,7940.71%0.49% to 1.03%
Gate precision: confirmed among decided flagged rowstrain52 of 18528.1%22.1% to 35.0%
Gate precision: confirmed among decided flagged rowstest1 of 128.33%1.49% to 35.4%
Confirmed train defects the 100x median outlier screen flagstrain47 of 5290.4%79.4% to 95.8%
Confirmed train defects the median screen or the diastolic rule flagstrain48 of 5292.3%81.8% to 97.0%
Confirmed train defects those two or a heart-rate or weight range check flagstrain51 of 5298.1%89.9% to 99.7%
Confirmed defects whose label the Verified pass rewrotetrain+test9 of 5317.0%9.20% to 29.2%
HOMA-IR training labels inflated 36x by the pmol/L conversiontrain32 of 7741.6%31.2% to 52.7%

Two things are not measured yet, because both need model calls and none has completed: how many defects the checks miss among unflagged rows, and how three models of different sizes answer the defect rows (339 calls planned, 1 attempted).

What finds them

Cheap screens find almost all of these rows. A screen that flags any label or input more than 100 times away from the median of its field (G4 below) catches 47 of the 52 train defects, and the label alone is that far out in 25. G3, the rule that diastolic pressure cannot exceed systolic, adds row 1545 for 48. Two plain range checks, heart rate from 15 to 300 bpm and weight up to 400 kg, add 2807 (heart rate 4,050 bpm), 5924 (weight 3,035 lb) and 6596 (heart rate 7,590 bpm) for 51. Those range checks flag 6 train rows in all; the others are 4737, 4865 and 6583. Their bounds were picked after the defects were known, so this shows how cheap the rows are to find, and it is not a held-out test of a screen. The last row, 5880, is caught by G2 because its stored insulin is not in the note. G4 at 30x instead of 100x would also catch it, and on its own would find 51 of the 52, but that threshold was also chosen after seeing the defects.

What reading the note adds is the cause and the answer the note supports. Row 2807 asks for a Wells score. Its note says pulse 40-50 bpm, the stored heart rate is 4050, and the stored label of 1.5 is exactly the 1.5 points the heart-rate criterion gives for a rate over 100. Read as 40-50, that criterion scores 0, not 1.5, so a model that reads the note correctly does not match the key. That reading is what decides what to do with a flagged row: relabel it when the note gives an answer (2807, or 1337 with an interval label), drop it when the note itself is wrong (the copied typos), and fix the calculator when one bug produced many rows (HOMA-IR above).

Where the defects are

Most of the copied typos sit in kidney and electrolyte formulas, where the note prints a unit such as mmol/dl for sodium or creatinine. The extraction defects are spread wider: platelet counts printed per 109/L stored a thousand times too small, heart-rate and weight ranges joined into one number, resected masses read as the patient's weight, and cerebrospinal fluid cell counts read as blood white cell counts. The largest groups are CKD-EPI (7), FIB-4 (6), Calcium correction (5) and SIRS (5).

Confirmed defects by calculator and type, train and test together, n = 53. The first 5 columns are extraction defects.
CalculatorRange mergedReadings mixedUnit tag wrongPower of ten lostOther extractionCopied typoTotal
CKD-EPI167
FIB-44116
Calcium correction145
SIRS2215
MDRD44
Maintenance fluids44
Albumin-corrected delta ratio33
Delta ratio22
Ideal body weight112
MAP112
Serum osmolality22
Albumin-corrected anion gap11
Albumin-corrected delta gap11
Anion gap11
BMI11
Cockcroft-Gault11
Delta gap11
Free water deficit11
HOMA-IR11
PERC11
Sodium correction11
Wells PE11
All calculators511693153

The four checks

Each check flags rows to read. A flag becomes a defect only after the note span that contradicts the input is quoted. Together the checks flagged 194 of 10,538 train rows and 12 of 1,100 test rows. Across all four, 52 of 185 decided flagged train rows are wrong labels (28.1%), which is the false-flag load a reviewer would face; test is 1 of 12.

The four checks on Verified train. A row can be flagged by more than one check. Unclear rows are left out of the decided count.
CheckWhat it testsRows flaggedDefects among decidedPrecision, 95% CIFalse flagsDefects only it flags
G1Recompute the label from the extracted inputs000
G2Every numeric input appears in the note13611 of 1328.33% (4.72% to 14.3%)1214
G3Diastolic at most systolic, MAP between them21 of 101
G4Label or input within 100x of the field's median6647 of 6275.8% (63.8% to 84.8%)1540

G1 is coded from the formula each row's own Ground Truth Explanation states, for 15 renal, electrolyte and blood-pressure formulas. It agrees with every stored label on the 3,794 rows it covers (upper 95% bound 0.10%). On the same rows of v1.2, 27 differ, all in CKD-EPI 2021. That matches PR #7 (open) on the Verified repo, which re-ran the calculators on both splits and reported 0 train mismatches. The maintainer's v1.0.8 release notes (2026-09-08) report 0 audit mismatches across all 11,693 rows, and commits 3df69cf and 192a585 fixed notes that contradicted their own entities: 8 sodium rows and the fentanyl units. So note-against-entity checks are already part of upkeep. G1 is here to show the formulas are right, so the remaining errors sit in the inputs.

G2 accepts a number that matches a note number times a power of ten from 10-3 to 103, to allow unit rescaling, and reports an input whose digits equal two note numbers joined across a hyphen as a merged range. Its precision is poor: 11 of 132 (8.33%). Of its 121 train false flags, 112 are number formats the reader does not parse, such as the decimal comma in 3,79, the space in 12 900 and the lost superscript in 16.4×104.

A format-aware reader, written after reading only a seeded random half of the G2-flagged train rows, handles decimal commas, spaces as thousands separators, a space after the decimal point, and a power of ten written without its superscript. On the other half, precision goes from 5 of 68 to 5 of 10 (50.0%, 95% CI 23.7% to 76.3%) and no defect is lost. On test it goes from 0 of 11 to 0 of 7. On the half it was written on, it goes from 6 of 64 to 2 of 9, and it drops 4 real defects: 4309, 4318, 4323 and 4347, platelet counts stored a thousand times too small. The old reader only caught those because it could not read "×109"; once it can, the 10-3 rescaling allowance accepts the wrong value. G4 still flags 4 of the 4. The format list was already known from the first pass over all rows, so the held-out half is held out for the exact rules, not for which formats exist. Every other number on this page uses the original reader.

G3 follows from definitions and needs no clinical bounds. It flagged 2 train rows and is the only check that fires on row 1545 below. G4 is a fixed 100x screen against the median of the same field in the same file, set before any flagged row was read. It finds the copied typos and needs a file large enough for the median to mean something.

9 train rows were marked unclear and are left out of every count: 4550, 6414, 6599, 6639, 6653, 6769, 6787, 6789 and 6805. Most give no unit or never state the input. 8 train rows have a wrong input that does not change the label; they count as not a defect.

On a second check, 4 of the unclear rows (6414, 6639, 6653 and 6769) look like the same patterns as counted rows, so 52 is a floor.

Worked examples

Each example shows the note sentence, the extracted input, the stored label, the recompute from the extracted input, and what the note supports, so the arithmetic can be redone by hand. Quotes are literal substrings of the row's Patient Note, and tests/test_handcheck.py checks that.

Row 1545: systolic and diastolic from different readings

The systolic input of 70 comes from a sentence about a drop in pressure, and the diastolic of 74 from a later reading. The stored MAP of 72.67 sits below its own diastolic input, which no MAP can do, and G3 caught it. The only pair the note states together was taken after ECMO cannulation on epinephrine and norepinephrine, and the question asks for values from admission before any treatment. So the note supports no answer: the task cannot be computed, and the label is a number for a question with none.

Row Number 1545, MAP, Verified train.
Note saysDespite these treatments, his systolic blood pressure dropped to 70 mmHg, and his respiratory condition deteriorated; he was intubated 5 days after the onset of symptoms, which is three days after...
Note saysAfter the procedure, the patient's SpO2 was 94%, heart rate was 131 beats/min, and blood pressure was 142/74 mmHg on 0.1 μg/kg/min of epinephrine and 0.3 μg/kg/min of norepinephrine.
Extracted inputsbp = 70 mm hg
Extracted inputdbp = 74 mm hg
Stored answer72.66667as stored in the CSV; rewarded from 69.03 to 76.30
Recomputed from the extracted inputs72.67
What the note supportsNone. The note gives no value this input could be replaced with, so the task has no supported answer.

Row 2685: a calcium range read as one value

The note gives calcium as a range, and the extracted input is a single value with the digits run together, 952.25 g/L. The unit the note prints, g/L, would give a corrected calcium near 200 mg/dL, which no patient has. The note's own reference range is the usual mmol/L range, so the blue interval assumes mmol/L. That is an assumption about a second typo in the source, and it is labeled as one.

Row Number 2685, Calcium correction, Verified train.
Note says...hemoglobin 149 g/L, red blood cells 5.37×1012/L, WBC 6.1×109/L, serum creatinine 87 μmol/L (reference range, 65-129 μmol/L) serum calcium 1.95-2.25 g/L (reference range, 2.10-2.55 g/L), serum albumin 35 g/L (reference range, 42-48 g/L), serum phosphorus 0.57-1.27 mmol/L (reference...
Extracted inputcalcium = 952.25 g/L
Stored answer95225.4as stored in the CSV; rewarded from 90,464 to 99,987
Recomputed from the extracted inputs95,225.4
What the note supports, if the note's g/L is read as mmol/L8.22 to 9.42 (7.80 to 9.89 with the 5% tolerance)

Rows 6171, 8473 and 8678: one note typo, three wrong labels

One note prints sodium in mmol/dl. The pipeline copied the unit as written, and the three calculators built on that note got labels of 1,230, 1,218 and -609. The note is wrong here, so this page gives no corrected answer and states only what each label rewards.

Rows 6171, 8473 and 8678, Verified train, all built on the same note and input.
Note says...filtration rate (GFR) >90 mL/min/1.73 m2, glucose of 66 mg/dl, blood urea nitrogen (BUN) of 12 mg/dl, creatinine of 0.68 mg/dl, sodium of 136 mmol/dl, potassium of 3.5 mmol/L, chloride of 104 mmol/L, CO2 of 26 mmol/L, calcium of 8.6 mg/dl, aspartate aminotransferase (AST) of 19 u/l,...
Extracted inputsodium = 136 mmol/dL
Row 6171, Anion gap1230.0as stored in the CSV; rewarded from 1,168.5 to 1,291.5
Row 8473, Delta gap1218.0as stored in the CSV; rewarded from 1,157.1 to 1,278.9
Row 8678, Delta ratio-609.0as stored in the CSV; rewarded from -639.45 to -578.55
What the note supportsNone. The note itself prints the impossible unit, so this page states only what the label rewards.

Row 267: an impossible creatinine unit copied from the note

The note prints creatinine in mmol/dl, the extraction copied it, and the stored GFR is 0.0009675 mL/min/1.73 m². Both the input and the label sit more than 100 times away from their medians in the file, which is what G4 measures. No interval, for the same reason as the sodium rows.

Row Number 267, CKD-EPI, Verified train.
Note saysCreatinine was 130 mmol/dl, and other blood works were within normal range.
Extracted inputcreatinine = 130 mmol/dL
Stored answer0.00096752as stored in the CSV; rewarded from 0.0009191 to 0.0010159
Recomputed from the extracted inputs0.0009675
What the note supportsNone. The note itself prints the impossible unit, so this page states only what the label rewards.

All confirmed rows

The full list, so any row can be checked against the dataset. It matches results/handcheck.csv and the draft issue in upstream/ISSUE.md.

Show all 53 rows (52 train, 1 test)
Every confirmed row, n = 53. Quotes are literal substrings of the row's Patient Note. Labels are as stored.
RowSplitCalculatorTypeNote saysStored inputStored label
34trainCockcroft-Gaultsource typo copiedcreatinine 78 mmol/Lcreatinine=78.0 mmol/L0.12759
255trainCKD-EPIsource typo copied1.05 µg/dLcreatinine=1.05 µg/dL540.37042
267trainCKD-EPIsource typo copiedCreatinine was 130 mmol/dlcreatinine=130.0 mmol/dL0.00096752
311trainCKD-EPIsource typo copiedcreatinine 120 mmol/Lcreatinine=120.0 mmol/L0.016671
409trainCKD-EPIsource typo copied119 to 270 mmol/Lcreatinine=270.0 mmol/L0.0057034
458trainCKD-EPIsource typo copiedcreatinine 25 mmol/Lcreatinine=25.0 mmol/L0.10711
467trainCKD-EPIsource typo copiedblood creatinine at 127 mmol/Lcreatinine=127.0 mmol/L0.011586
2533trainBMIsource typo copiedheight: 1.78 cmheight=(1.78, 'cm')220931.70054
2572trainCalcium correctionsource typo copiedAlbumin: 2.5 mg/dLalbumin=2.5 mg/dL14.298
2593trainCalcium correctionsource typo copiedAlbumin 4.3 mg/dLalbumin=4.3 mg/dL12.09656
2665trainCalcium correctionsource typo copiedAlbumin: 3.6 mg/dL / Ca2+: 7.0 mEq/Lalbumin=3.6 mg/dL; calcium=7.0 mEq/L17.22512
2673trainCalcium correctionsource typo copiedAlbumin 3.2 mg/dLalbumin=3.2 mg/dL12.09744
3175trainMDRDsource typo copiedcreatinine 877 mol/lcreatinine=877.0 mol/L4.7378e-07
3211trainMDRDsource typo copiedcreatinine was 1.1 μmol/Lcreatinine=1.1 µmol/L11632.92792
3337trainMDRDsource typo copiedelevated at 120 mmol/lcreatinine=120.0 mmol/L0.018366
3394trainMDRDsource typo copiedelevated at 254 mmol/Lcreatinine=254.0 mmol/L0.0097267
3794trainIdeal body weightsource typo copiedheight of 155 metersheight=(155.0, 'm')13942.94065
4368trainFIB-4source typo copiedblood platelet count of 109,000/Lplatelets=109000.0 L26402211.47939
5439trainSodium correctionsource typo copiedsodium 143 mmol/mLsodium=143.0 mmol/mL143003.312
5564trainSerum osmolalitysource typo copiedglucose 61 g/dL / urea 102.72 mg/dLglucose=61.0 g/dL; bun=102.72 mg/dL3683.5746
5768trainSerum osmolalitysource typo copiedfasting blood sugar: 90 mmol/dLglucose=90.0 mmol/dL1171.44286
6171trainAnion gapsource typo copiedsodium of 136 mmol/dlsodium=136.0 mmol/dL1230.0
6660trainSIRSsource typo copiedWhite blood cell count was 11.6 cells/microLwbc=11.6 µL3
8473trainDelta gapsource typo copiedsodium of 136 mmol/dlsodium=136.0 mmol/dL1218.0
8678trainDelta ratiosource typo copiedsodium of 136 mmol/dlsodium=136.0 mmol/dL-609.0
8853trainDelta ratiosource typo copiedserum sodium 124 mEq/mLsodium=124.0 mEq/mL; chloride=89.0 mEq/mL; bicarbonate=15.0 mEq/mL-1.33467
8935trainAlbumin-corrected anion gapsource typo copiedAlbumin: 2.5 mg/dLalbumin=2.5 mg/dL18.99375
8980trainAlbumin-corrected delta gapsource typo copiedAlbumin: 2.5 mg/dLalbumin=2.5 mg/dL6.99375
8997trainAlbumin-corrected delta ratiosource typo copiedS.albumin 3.2 mg/dlalbumin=3.2 mg/dL-0.18173
9027trainAlbumin-corrected delta ratiosource typo copiedAlbumin: 2.5 mg/dLalbumin=2.5 mg/dL-3.49688
4309trainFIB-4multiplier droppedplatelets 140 × 109 l−1platelets=140000000.0 L2273.48119
4318trainFIB-4multiplier droppedplatelets 213 × 109/Lplatelets=213000000.0 L1691.60545
4323trainFIB-4multiplier droppedplatelet count of 294 × 109/Lplatelets=294000000.0 L3705.36697
4347trainFIB-4multiplier droppedplatelet 398×109/L / AST 0.42 ukat/L / ALT 0.6 ukat/Lplatelets=398000000.0 L; ast=0.42 U/L; alt=0.6 U/L31.33419
6640trainSIRSmultiplier droppedwhite blood cell count=6.3×109/Lwbc=6.3 L3
6801trainSIRSmultiplier droppedWhite blood cell count was 6.4×109/Lwbc=6.4 L3
463trainCKD-EPIotheraround 200mol/Lcreatinine=200.0 mmol/L0.0087006
4336trainFIB-4otherplatelet count was 111*109/L / alanine aminotransferase (ALT): 41 IU/L / (AST): 41 IU/L / ALT: 52 U/L, AST: 54 U/L / 297*109/L after 18 daysplatelets=297000000.0 L; ast=54.0 U/L; alt=52.0 U/L1664.10059
4711trainMaintenance fluidsotherwith a weight of 500 gramsweight=500.0 g2.0
4943trainMaintenance fluidsotherThe weight of the cyst was around 300 gweight=300.0 g1.2
4981trainMaintenance fluidsotherThe specimen weighted 260 gweight=260.0 g1.04
5088trainMaintenance fluidsotherweighed 270 gweight=270.0 g1.08
5880trainHOMA-IRotherinsulin level of 21 pmol/lInsulin=756.0 pmol/L1089.76
6665trainSIRSotherThe lumbar puncture results showed a pressure of 23 cm·H2O, a white blood cell count of 2wbc=2.0 µL2
6732trainSIRSother(white blood cell count – 20) / His hematological and biochemical parameters were normalwbc=20.0 µL4
1337trainMAPrange merged150-160/80-90 mmHg / baseline of 100-130/70-80 mmHgsbp=150160.0 mm hg; dbp=8090.0 mm hg55446.66667
2685trainCalcium correctionrange mergedserum calcium 1.95-2.25 g/Lcalcium=952.25 g/L95225.4
2807trainWells PErange mergedpulse 40-50 bpmheart_rate=4050.0 beats per minute1.5
5924trainFree water deficitrange mergedweight loss (approximately 30–35 lb)weight=3035.0 lbs-26.54971
6596trainPERCrange mergedheart rate range of 75-90 beats per minute / discharged on Leuprolide Depot 11.25 mg injections every three months and norethindrone hormonal therapyheart_rate=7590.0 beats per minute; Hormone use=True2
1545trainMAPreadings mixedsystolic blood pressure dropped to 70 mmHg / blood pressure was 142/74 mmHg on 0.1 μg/kg/min of epinephrine and 0.3 μg/kg/min of norepinephrinesbp=70.0 mm hg; dbp=74.0 mm hg72.66667
3703trainIdeal body weightunit tag does not match noteher height was 160 mmheight=(160.0, 'm')14395.6968
877testAlbumin-corrected delta ratiosource typo copiedAlbumin 3.5 mg/ dLalbumin=3.5 mg/dL5.49563

Method

The four CSVs (Verified and v1.2, train and test) are downloaded from pinned Hugging Face commits and checked against sha256 before anything runs. Joined on Calculator ID plus Note ID, 331 of 10,538 train labels differ between v1.2 and Verified by more than 1e-6. Of those, 57 differ by less than 0.01%, which is re-rounding; 219 differ by more than 0.1%, and 147 by more than the dataset's 5% tolerance. On test, 35 of 1,099 differ, 23 of them by more than 5%.

Every flagged row has a line in results/handcheck.csv with the checks that fired, the quoted note span, the stored input and label, a decision, a defect type from a fixed list, and the note inputs where they can be computed. A row is a defect when the input contradicts the note, or the note prints an impossible unit that was copied, and correcting the input changes the label or leaves the task with no answer. A copied typo is called only where the note prints the unit literally and G4 fired. Each flagged row has a first-pass call and reason. Dev then read every defect and unclear row (62 in all) against its note on 2026-10-18 and agreed with each call. The 144 rows called not a defect keep their first-pass call. Most calls are a quote plus arithmetic. Some are contextual clinical reads: whether a cell count came from cerebrospinal fluid or blood (6665, 6732 and 6805), whether a pressure on pressors counts as pre-treatment (1545), and whether a weight is the patient's or a resected mass's (4711, 4943, 4981 and 5088). None of them was made by a clinician, and a clinician may overrule any of them.

For a range in the note, the label is computed over every combination of endpoints and widened by the 5% tolerance. For mixed readings, it uses pairs stated together in one reading. For a unit tag that does not match, it uses the unit the note prints, unless that unit is itself impossible; for a lost power of ten, it restores it; for an input taken after treatment, it uses the pre-treatment value the note gives. Copied typos get no interval. 11 extraction rows have one, and a test checks that no stored label falls inside its own interval.

The model step is written and not run. It sends the zero_shot system and user strings from MedCalc-Bench's evaluation/run.py, verbatim, through the command in scripts/run_models.py with tools off, and caches every raw response before parsing: 100 re-extractions of unflagged rows by the mid-size model to estimate misses, 53 defect rows on each of three models of different sizes, and 40 clean control rows on the two smaller ones. Per 1,000 training rows, 2.09 carry an extraction defect (22 of 10,538).

Prior work, cited for what it covers. arXiv 2512.19691 audited the v1.0 test labels, estimating at least 27% are likely erroneous or incomputable, and recomputed labels from the note alone for a random half of the v1.0 training split. Its RL experiment trained on 4,593 of those relabeled training rows and beat training on the original labels by 13.5 points. It does not list which training rows were wrong or why, and it predates Verified. It names feature-extraction errors as a cause of wrong labels; this gate finds them on the training split without a model, by checking each Relevant Entity against a quoted span of its note, and lists each row. arXiv 2603.02222 fixes over 20 calculator implementation errors, including the HOMA-IR conversion above. arXiv 2509.16584 scores formula, extraction and arithmetic steps separately in model outputs. PR #7 re-ran the calculators and reported 0 train mismatches.

All 52 rows are inherited from v1.0. 27 fell in 2512.19691's training sample, and its released labels already disagree with the stored label on 18 of them, without naming the rows or the cause. The remaining 34 of the 52 have no public corrected label that a search on October 18, 2026 found, and none of the 52 is fixed in Verified v1.0.8.

Limitations

Rerun

From the labelgate folder. The gate needs no model calls. The library uses only the Python standard library; the tests need pytest.